TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
72149 ELECTRONIC TRANSFORMER CORP.

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ACZB FREQUENCY RATING 420.0 HERTZ NOMINAL SINGLE COMPONENT
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 24.5 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY
ADAQ BODY LENGTH 6.500 INCHES NOMINAL
ADAT BODY WIDTH 4.062 INCHES NOMINAL
CWJS WINDING OPERATING VOLTAGE 220.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 206.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 242.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 254.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
ADAU BODY HEIGHT 5.094 INCHES NOMINAL
CMLP THREAD QUANTITY PER INCH 20 SINGLE GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 5.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/NEUTRAL TAP SINGLE COMPONENT SINGLE PRIMARY
TTQY TERMINAL TYPE AND QUANTITY 19 STANDOFF, SOLDER LUG
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 6.25 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AKNA INCLOSURE TYPE HERMETICALLY SEALED
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
CQJX NOMINAL THREAD SIZE 0.250 INCHES SINGLE GROUP
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP